  Datasheet File OCR Text:
  input parameter conditions min. typ. max. units input voltage range 90 264 vac 100 375 vdc input frequency 47 440 hz input current see model selection guide inrush current 115 vac 30.0 a pk 230 vac 50.0 emi meets cispr pub. 22/fcc class b output parameter conditions min. typ. max. units output voltage see model selection guide output current see model selection guide output voltage accuracy see note 1 ?.0 % line regulation, see note 2 v in = min to max ?.5 % load regulation, single output i o = 1% to 100% ?.0 % load regulation, dual output, see note 3 i o = 10% to 100% ?.0 % load regulation, triple output - primary i o = 10% to 100% ?.0 % load regulation, triple output - aux. i o = 10% to 100% ?.0 % cross regulation, dual output, see note 4 i o = 15% to 100% ?.0 % cross regulation, triple output - primary i o = 15% to 100% ?.0 % cross regulation, triple output - aux. i o = 15% to 100% ?.0 % ripple & noise (20 mhz) 3.3 vdc output 50.0 mv p-p all other outputs 1.0 %v p-p of v o hold-up time 115 vac 15 msec temperature coef cient ?.02 %/? over temperature protection note 4 100 ? over voltage protection zener diode clamp 120 % of v o short circuit protection, see note 6 continuous (autorecovery) overload protection 105 120 % of i o general parameter conditions min. typ. max. units isolation voltage input to output 3,000 vac isolation resistance 500 vdc 100 m  emi/rfi conducted en 55022 level b emc compliance electrostatic discharge (esd) en 61000-4-2 level b rf field susceptibility en 61000-4-3 electrical fast transients/bursts on mains en 61000-4-4 level 3 2 kv surge en 61000-4-5 level 3 1kv/2 kv switching frequency 132 khz environmental parameter conditions min. typ. max. units operating temperature range ambient -40 +25 +70 ? operating temperature range case +95 ? storage temperature range -40 +100 ? cooling free air convection (see derating curve) humidity rh, non-condensing 95 % physical case size 3.50 x 2.50 x 0.98 inches (89.0 x 63.5 x 25.0 mm) case material non-conductive plastic& fiberglass (ul94-v0) weight 9.85 oz (280g) reliability speci cations parameter conditions min. typ. max. units mtbf mil hdbk 217f, 25?, gnd benign 200 400 khours safety standards en 60950 safety class iec 61140 class ii board mount, 40w single, dual & triple out ac/dc power supplies mpm-40 series electrical speci cations speci cations typical @ +25?, 230 vac input voltage & rated output current, unless otherwise noted. speci cations subject to change without notice. key features: 40w output power universal 90-264 vac input en 60950 approved (ul) meets iec safety class ii industry standard pin-out single, dual & triple outputs meets en 55022 b >200 khour mtbf chassis mount models & din rail mount option available! micropower direct 292 page street suite d stoughton, ma 02072 usa t: (781) 344-8226 f: (781) 344-8481 e: sales@micropowerdirect.com w: www.micropowerdirect.com www.micropowerdirect.com
model selection guide notes: all dimensions are typical in inches (mm) tolerance x.xx = 0.01 ( 0.25) pin single dual dual seperate triple 1 ac-line 2 ac-neutral 3 +vo +vo +vo 2 +vo 2 4 no pin no pin +vo 1 +vo 1 5 -vo common -vo 2 common 2/3 6 no pin no pin -vo 1 -vo 1 7 nc -vo no pin -vo 3 nc = no connection dual separate models = mpm-40d-0512 & mpm-40d-0524 pin connections model number input output 1 (vout 1) output 2 (vout 2) output 3 (vout 3) ef ciency (%, typ) current (a) voltage (vdc) current voltage (vdc) current voltage (vdc) current (a) 115 vac 230 vac max. (a) min. (%) max. (a) min. (%) max. (a) min. (%) mpm-40s-03 0.860 0.460 3.3 8.000 1.0 76 mpm-40s-05 0.860 0.460 5.0 8.000 1.0 81 mpm-40s-09 0.860 0.460 9.0 4.444 1.0 83 mpm-40s-12 0.860 0.460 12.0 3.333 1.0 84 mpm-40s-15 0.860 0.460 15.0 2.666 1.0 83 mpm-40s-24 0.860 0.460 24.0 1.667 1.0 83 mpm-40d-05 0.860 0.460 +5.0 +4.000 10.0 -5.0 -4.000 10.0 81 mpm-40d-12 0.860 0.460 +12.0 +1.666 10.0 -12.0 -1.666 10.0 83 mpm-40d-15 0.860 0.460 +15.0 +1.333 10.0 -15.0 -1.333 10.0 83 mpm-40d-0512 0.860 0.460 5.0 5.000 25.0 12.0 1.250 25.0 82 mpm-40d-0524 0.860 0.460 5.0 5.000 25.0 24.0 0.625 25.0 82 mpm-40t-0512 0.860 0.460 +5.0 +5.000 25.0 +12.0 +0.600 25.0 -12.0 -0.600 25.0 82 mpm-40t-0515 0.860 0.460 +5.0 +5.000 25.0 +15.0 +0.500 25.0 -15.0 -0.500 25.0 81 derating curve mechanical dimensions other output combinations are available contact the factory for details at: sales@micropowerdirect.com micropower direct we power your success - for less! 292 page street ste d stoughton, ma 02072 tel: (781) 344-8226 fax: (781) 344-8481 e-mail: sales@micropowerdirect.com www.micropowerdirect.com notes: 1. for dual output models mpm-40d-0512 and mpm-40d-0524 , output voltage accuracy is ?% for ouput 1 and ?% for output 2. for triple output models, the output voltage accuracy is ?% for output 1 and ?% for output 2 & 3. 2. for the mpm-40d-0512 and mpm-40d-0524 , the line regulation of output 2 is speci ed at ?%. 3. for models mpm-40d-05, mpm-40d-12 and mpm-40d-15 , load regulation is measured with balanced loads. for the mpm-40d-0512 and mpm-40d-0524 , load regulation is ?% for output 1 and ?% for output 2. 4. for the mpm-40d-0512 and mpm-40d-0524 , cross regulation is measured for a load change of 25% to 100%. it is ?% for output 1 and ?% for output 2. 5. the overtemperature protection circuit will shut the unit down. the unit will restart when the operating temperature drops to approximately +80?. 6. output short circuit protection is provided by a ?iccup mode circuit. the unit recovers automatically when the fault condition is removed. 7. operation at under no load conditions will not damage these units, however the output voltage may be unstable. it is recommended that the minimum load values in the table above be used. 8. the maximum capacitive load for these units ranges from 23,000 f (mpm-40s-03 ) to 470 f (mpm-40s-24 ). contact technical sales for information on speci c models. 9. it is recommended that a fuse be used on the input of a power supply for protec- tion. for the mpm-40 series, a 2a/250 vac slow blow should be used. model number


▲Up To Search▲   

 
Price & Availability of MPM40S03

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X